SAPLAST · Certificates
SOLAR PROTECTION
COOL-LITE® SKN
COOL-LITE SKN
DESCRIPTION
COOL-LITE SKN is a range of products whose coatings provide high performance in both solar control and thermal insulation. The coatings are applied to PLANICLEAR® clear float glass by cathodic sputtering under vacuum conditions.
APPLICATION
Thanks to their unique properties, these glass products are ideally suited to applications with a high glazing ratio, where energy consumption for heating/cooling must be kept as low as possible while maintaining abundant natural light.
This glass meets the highest aesthetic requirements, giving the building additional personality and elegance. The space takes on a warm atmosphere, while its connection to the surroundings adds comfort and revitalises the spirit
ADVANTAGES
COOL-LITE SKN glass combines the benefits of high-performance solar control and thermal insulation with those of neutral glass: Very low g-value; Excellent thermal insulation coefficient: Ug? 1,1 W/m K High light transmission; Reduced reflection; High neutrality in both transmission and external reflection.
COOL-LITE SKN products can be used to create more comfortable interiors by significantly reducing the greenhouse effect and the need for costly air conditioning. During the cold season, COOL-LITE SKN provides a high level of thermal insulation while significantly reducing excessive heat loss.
In line with these characteristics, we can use larger glazing areas, achieving a high contribution from natural light and visual comfort.This reduces costs associated with artificial lighting and creates a healthier living environment.
WINTER
SUMMER
TL – Light transmission, TE – energy transmitted directly, RE – reflected energy, qe=the portion of absorbed energy radiated outside, qi – the portion of absorbed energy radiated inside, g – solar factor (total transmitted energy)
Range
| SGG COOL - LITE ST | 4 mm | 6 mm | 8 mm | 10 mm | 12 mm |
|---|---|---|---|---|---|
| COOL - LITE SKN 176/176 II | On request | x | x | x | On request |
| COOL - LITE SKN 174/174 II | On request | x | x | x | On request |
| COOL - LITE SKN 165/165 II | On request | x | x | x | On request |
| COOL - LITE SKN 154/154 II | On request | x | x | x | On request |
| COOL - LITE SKN 144 II | On request | x | x | x | On request |
Performance
| 6/16 Ar/4 coating on face #2 | SKN 176/176 II | SKN 174/174 II | SKN 165/165 II | SKN 154 II/154 II | SKN 144 II |
|---|---|---|---|---|---|
| Light factors (EN 410) | |||||
| Transmission TL % | 70 | 69 | 61 | 52 | 41 |
| External reflection, R loc % | 13 | 11 | 16 | 19 | 20 |
| Internal reflection, R int % | 15 | 13 | 18 | 22 | 18 |
| UV transmission | 19 | 28 | 21 | 22 | 18 |
| Energy factors (EN 410) | |||||
| Direct transmission, TE % | 35 | 39 | 32 | 26 | 20 |
| External reflection, Rext % | 37 | 31 | 37 | 37 | 31 |
| External absorption A1 | 27 | 29 | 30 | 36 | 48 |
| Internal absorption A2 | 1 | 1 | 1 | 1 | 1 |
| Solar factor, g | 0,37 | 0,41 | 0,34 | 0,28 | 0,23 |
| Shading coefficient | 0,43 | 0,47 | 0,39 | 0,32 | 0,26 |
| Thermal insulation coefficient, U (EN 673) | |||||
| W/m²K | 1,0 | 1,1 | 1,0 | 1,1 | 1,1 |
| Selectivity, S | 1,89 | 1,89 | 1,79 | 1,86 | 1,78 |
Standards and regulations
COOL-LITE SKN / SKN II meets the Class C durability requirements of European standard EN 1096, 1 and 2.